Two professionals reviewing a QR-coded industrial battery pack and technical records in a manufacturing facility for EU Battery Passport 2027 readiness.

EU Battery Passport: What to Ask Your Suppliers Before 2027

A supplier could send you a spreadsheet with all 71 data points completed and still leave the key question unanswered: does it describe the finished battery you are buying, and does it include the fields required for that battery category in February 2027? The EU Battery Passport does not mean every field must be completed at launch. Some apply only in certain circumstances; others must not yet be filled in or displayed.

From 18 February 2027, each electric vehicle (EV) battery, each light means of transport (LMT) battery and each industrial battery with a capacity greater than 2 kWh that is placed on the EU market or put into service must have a digital Battery Passport. The European Commission’s version 3.2 data-point guidance, dated 19 October 2026 sets out 71 data points and their applicability by battery category. Buyers should start with the relevant category column, not a blanket request for 71 completed fields.

The practical test is whether the information relates to the finished battery being purchased, identifies the responsible operator and can be accessed and maintained throughout the battery’s life.

Which Batteries Need an EU Battery Passport in 2027?

Article 77 of Regulation (EU) 2023/1542 sets the scope. From 18 February 2027, the requirement applies to every EV battery, every LMT battery and every industrial battery with a capacity greater than 2 kWh that is placed on the EU market or put into service. The obligation attaches to the battery, including a covered finished battery incorporated into a vehicle, machine or other product. It does not automatically apply to the vehicle or machine as a whole.

The relevant unit is the finished, safely functioning battery. Cells or modules imported as components for assembly in the EU are not normally treated as finished batteries by themselves. Where several packs rely on a common battery management system (BMS) or other shared components and work together as one functioning battery, the system may require one Passport. If the packs function independently, each is assessed separately. The Commission says these cases, including the 2 kWh threshold, need to be assessed on their facts. Its Battery Passport FAQ explains the distinction.

Who Is Responsible for the EU Battery Passport?

Responsibility normally sits with the economic operator that places the finished battery on the EU market or puts it into service. This is often the manufacturer or importer, but the answer can change where another EU business completes a battery system before placing it on the market.

If an EU battery manufacturer supplies a completed battery to a vehicle manufacturer that only installs it, the battery manufacturer generally remains responsible. If the vehicle manufacturer completes the battery, for example by adding a BMS or another component essential to safe operation, responsibility may sit with that manufacturer. An EU business importing a finished battery from outside the Union will normally be responsible as the operator placing it on the market.

A supplier or specialist can be authorised in writing to create or update the Passport. That does not transfer the legal responsibility. The economic operator responsible for the battery must ensure that the information is accurate, complete and up to date, and that the Passport is registered. Buyers should confirm which legal entity owns this obligation before treating a supplier template or assurance as sufficient.

What Changed in the October 2026 Guidance?

Version 3.2 of the Commission’s guidance clarifies data formats, the source of individual requirements, public and restricted access, and applicability by battery category. It adds a new optional discharge C-rate field (data point 40), updates the treatment of replacement-spare information and clarifies the applicability of individual-battery fields 51–66 to certain industrial batteries. It also explains the expected format for histogram data in fields 70 and 71.

These are implementation clarifications, not a new law. The Commission says the guidance does not extend the rights or obligations in the legislation or introduce additional requirements. Read it alongside the Batteries Regulation and any relevant delegated or implementing acts. For the broader context, see VECTRA’s guide to Digital Product Passport governance and traceability. 

What Battery Passport Information Should Buyers Request?

The Commission matrix classifies each data point as mandatory, optional, conditional, or not to be filled in or displayed as of February 2027. Status differs across EV, LMT and industrial batteries, so assess each entry against the relevant category and technical conditions.

Information groupFebruary 2027 position
Identification and responsible operator (1–9)Core identity fields are mandatory across the three covered categories. Manufacturer website and email are optional where available.
Core characteristics and composition (10–15 and 24)Weight, capacity, chemistry, specified hazardous substances, usable extinguishing agent and critical raw materials above 0.1% are mandatory. Renewable-content share (24) is also mandatory.
Performance and durability (26–40)Applicability varies by category and technical conditions. Many fields are mandatory; warranty data is conditional. Discharge C-rate (40) is optional.
Marking, conformity and waste (41-44)The separate-collection marking under Article 13(4) (41) is mandatory; the cadmium/lead symbol under Article 13(5) (42) applies where relevant. The EU declaration of conformity (43) and waste-battery information (44) are mandatory.
Instructions for use (45)Not to be filled in or displayed at the February 2027 launch under version 3.2 of the Commission guidance, pending the relevant Omnibus provisions.
Carbon footprint, responsible sourcing and recovered content (17–19 and 20–23)Not to be filled in or displayed at launch. The underlying legal timetables and implementing measures differ by field.
Restricted technical information (46-50)Detailed composition (46), components and replacement-spare sources (47), dismantling (48), safety (49) and compliance test reports (50) are required, with access restricted according to the type of information.
Individual and dynamic information (51–71)Requirements vary by category. Use-generated data may initially be empty for a new battery if it does not yet exist; required status and applicable performance/durability information cannot simply be deferred.

Use the table as an overview when reviewing a supplier response. For a specific battery, check the Commission’s detailed data-point guidance, particularly where technical applicability or access restrictions are relevant.

Which EU Battery Passport Data Is Mandatory at Launch?

Start with the battery’s identity and core product data. The first data points identify the unique battery, the person registering or responsible for the Passport, the manufacturer’s name and postal address, the battery category, model or batch/serial identifier, manufacturing location and manufacturing date. The manufacturer’s website and email address are optional when available.

The basic product information also includes weight, capacity, chemistry, hazardous substances other than mercury, cadmium or lead, a usable extinguishing agent and critical raw materials present above 0.1% by weight. These values should describe the actual battery model or configuration. A generic product-family description is not enough where the chemistry, capacity or design differs between variants.

One field is easy to overlook: the share of renewable content (data point 24) is mandatory for EV, LMT and covered industrial batteries. It should not be confused with recovered-content percentages for cobalt, lithium, nickel and lead (data points 20–23), which are not to be filled in or displayed at the February 2027 launch. Data point 16 repeats material-composition information already captured elsewhere, while data point 25 repeats rated capacity in data point 11. Neither is a separate missing field.

The performance and durability section covers voltage, power capability, temperature ranges, expected lifetime, efficiency, internal resistance and cycle-life testing. Many fields are mandatory, but applicability differs. Expected lifetime in cycles and its reference test are mandatory for EV and LMT batteries and apply to industrial batteries where lifetime can appropriately be expressed in cycles. The capacity threshold for exhaustion is required for EV batteries, but not to be filled in or displayed for LMT or industrial batteries. Round-trip efficiency fields are mandatory for EV and LMT batteries and apply only to some industrial batteries. Warranty duration is required where a commercial warranty is envisaged.

Charge C-rate (data point 39) is mandatory for EV and LMT batteries and applies to some industrial batteries. The new discharge C-rate field (data point 40) is optional across all three categories. Buyers should request the relevant value and test reference rather than impose one template on every industrial battery.

For marking and conformity, data point 41 covers the separate-collection marking under Article 13(4), while data point 42 covers the cadmium or lead symbol under Article 13(5), where applicable. The EU declaration of conformity (data point 43) and waste-battery prevention and management information under Article 74(1) (data point 44) are mandatory across the three covered categories.

Which Fields Can Wait Until Later?

Some fields are intentionally not to be filled in or displayed at launch because their underlying requirements follow a later timetable or await further implementing measures. Their absence should therefore be assessed against the October 2026 matrix, rather than treated automatically as a supplier compliance gap.

Carbon-footprint declaration and label (data points 17 and 18) are not to be filled in or displayed in February 2027 because the format is still to be specified in an implementing act. Responsible-sourcing information (data point 19) follows the battery due-diligence timetable. Regulation (EU) 2025/1561 postponed those due-diligence obligations to 18 August 2027. Recovered-content fields (data points 20–23) follow Article 8 and the relevant delegated act. By contrast, renewable content (data point 24) is required at launch.

Instructions for use (data point 45) are marked as not to be filled in or displayed at the February 2027 launch under version 3.2 of the Commission guidance, with the relevant application provisions on hold pending Omnibus adoption. This describes the guidance position for the Passport field; it does not remove separate product-safety or information obligations.

This distinction matters when preparing a supplier request. A missing carbon-footprint label at launch is different from a missing manufacturer identifier or renewable-content share. Buyers may still request information for later obligations or internal sourcing policies, but should identify it as preparation for a future requirement rather than a current Passport-field requirement.

How Should Buyers Handle Restricted and Dynamic Information?

Not all mandatory Passport information is public. Restricted data points 46-49 cover detailed battery composition (46), component part numbers and sources of replacement spares (47), dismantling information (48) and safety measures (49). Access is intended for persons with a legitimate interest, notified bodies, Member State authorities and the Commission, subject to the final access rules. Data point 50 covers compliance test reports and has narrower access, limited to notified bodies, relevant authorities and the Commission.

On October 19, 2026, the European Commission published draft rules on access to restricted Battery Passport data. The draft does not establish final access rights. Ask the responsible operator how restricted records will be made available to eligible parties and what your team can access in its role as a buyer.

The Passport also contains information specific to an individual battery and information that may change during use. The matrix sets category-specific conditions for these fields. Use-generated information, such as charging cycles, negative events and operating conditions, may initially be empty when a new battery is registered because the operating history does not yet exist.

That does not mean every dynamic field can be left blank. Battery status and the applicable performance and durability values still need to be available when the battery is placed on the market and reviewed when its status changes. The Commission FAQ explains that state-of-health requirements apply only where a battery has a BMS; the same exception does not automatically extend to other use-related data under Annex XIII, point 4(d). Real-time transmission is not a general requirement. At a minimum, the relevant data must be updated when a change in battery status occurs or is being considered, for example before repurposing, remanufacturing or recycling.

Where repurposing or remanufacturing requires a new Passport, the new record must be linked to the previous Passport under Article 77(7). Buyers should therefore check how the responsible operator will preserve that link and maintain traceability across the battery’s lifecycle.

How Can Buyers Verify EU Battery Passport Readiness?

Beyond the dataset, buyers need to check how the Passport will be registered, accessed and maintained for the specific battery being purchased.

How Are Digital Registration and Access Managed?

The DPP Registry became operational on 20 July 2026. It is not a central database containing every Passport field. The responsible economic operator, or an operator authorised in writing, hosts the detailed Passport information and manages access. The Registry records registration information and metadata and supports access by public authorities where the rules allow it. The Registry’s implementation arrangements are set out in Commission Implementing Regulation (EU) 2026/1778.

The QR code is the entry point, not proof by itself that the Passport is complete or that registration and access arrangements work. Ask how the battery identifier links to the hosted record, who is responsible for registration and who will maintain the information. The Commission FAQ also confirms that the Battery Passport registration identifier does not need to be entered in the electronic customs declaration.

Buyers should also check language arrangements. Information required under the Batteries Regulation must be available in a language easily understood by end users, as determined by the relevant Member State. Where the battery will be supplied across several EU markets, clarify how the applicable language requirements will be met.

What Should Buyers Request from Suppliers Now?

For each battery model or finished system, the request should help the buyer assess readiness for procurement or import. It should cover five areas:

1.    The finished battery. Identify its category, capacity and product identifier. Explain whether imported cells, modules or packs are assembled into a finished battery in the EU.

2.    The responsible operator. Name the legal entity placing the finished battery on the EU market or putting it into service, and confirm who is accountable for the Passport.

3.    The launch dataset. Provide the mandatory identity, product, composition, safety, renewable-content and applicable technical information for that battery category, with supporting records.

4.     Exceptions and later fields. Explain why an entry is optional, conditional, duplicated or not to be filled in or displayed in February 2027. Keep later carbon-footprint, recovered-content and due-diligence work on a separate timetable.

5.     Digital arrangements. Confirm who creates, hosts, registers, and updates the passport. Check that the QR code opens the record for the correct battery, and ask how eligible parties will access restricted information. 

Record each unresolved gap, who will fix it, and by when. If you’re sourcing from a new supplier, review any open battery passport gaps as part of supplier onboarding before approving the supplier. 

Before requesting Passport data, buyers should confirm the supplier entity, manufacturing site, battery model and responsible economic operator. For complex supply chains, VECTRA’s Supply Chain Mapping guide can help identify who holds the relevant information.

Supplier requests should focus on the applicable February 2027 requirements, supporting evidence and unresolved gaps. VECTRA’s Supplier Engagement guide explains how to make these requests specific and proportionate. Where the review reveals broader supplier-risk or regulatory due-diligence gaps, VECTRA’s Compliance, Risk & Due Diligence service can support further assessment.

The priority is to establish whether the finished battery will have accurate, traceable and accessible Passport information, rather than simply collecting a completed spreadsheet.

SUMMARY

Who: The economic operator that places a covered battery on the EU market or puts it into service is responsible for the passport. Procurement teams should confirm who that is before requesting supplier data.

What: An electronic passport is required for each electric vehicle battery, light means of transport battery, and industrial battery with a capacity greater than 2 kWh.

When: The requirement starts on February 18, 2027.

Where: It applies in the EU, including to covered batteries incorporated into vehicles, machinery, or other products.

Why: Buyers need to know which information is required for the finished battery, who will maintain it, and how it can be accessed.

Frequently Asked Questions

Does Every Battery Need an EU Battery Passport in February 2027?

No. The requirement covers finished EV batteries, LMT batteries and industrial batteries with a capacity greater than 2 kWh that are placed on the EU market or put into service. Ordinary portable batteries and unfinished components are not automatically covered by this Passport requirement.

Must Suppliers Complete All 71 EU Battery Passport Data Points?

No. The Commission matrix distinguishes mandatory, optional, conditional and not-to-be-filled-or-displayed fields. Applicability differs by battery category, and some entries repeat information already captured elsewhere. Use the relevant category column rather than treating every blank cell as a gap.

Can a Supplier Create an EU Battery Passport on Behalf of the Buyer?

Yes. The responsible economic operator may authorise another operator in writing to create or update the Passport. The authorisation does not transfer legal responsibility. The operator placing the finished battery on the EU market remains responsible for the Passport and its required information.

View Related Posts

·       Supplier Onboarding: 9 Risk Controls 

·       Supply Chain Mapping: 8 Blind Spots Hiding Supplier Risk

·       Supplier Engagement: How to Get Better Evidence and Close Risk Gaps

VECTRA International is a trusted Business Resilience & Operational Capability Building Partner. Through our ecosystem of integrated solutions, we help organizations transform operational complexity into resilient performance, measurable business impact, and sustainable growth.

Chaussée de Wavre 1517B, 1160 Brussels, Belgium.

A Note on Our Visuals: At VECTRA, we combine human expertise with advanced technology. Some of the supportive imagery in this article was generated using artificial intelligence tools like Google Gemini. We ensure all conceptual AI assets align with our brand standards and accurately reflect our data.

Table of Contents

RECENT BLOGS

LATEST PRESS RELEASE

Grab Your Free eBook Today!

Stay ahead of evolving ESG regulations and learn how to meet compliance requirements while strengthening business resilience.